Ball Mill Motor Retrofit in The Building Materials Industry

Case Study
 

 

Before 

 

The original system used a traditional asynchronous motor + gearbox drive, which resulted in:

  • High energy consumption
  • Complex transmission structure
  • Frequent maintenance requirements

Motor Type: Asynchronous Motor
Rated Power: 200 kW
Control Method: Star-delta starting (50 Hz)
Transmission: Gearbox (ratio 1:4)

a608481b63445b2d1367fcacf0b154f0

After  

 

Solution: Permanent Magnet Synchronous Motor (PMSM) + Variable Frequency Drive (VFD)

Average operating power: 105.5 kW

Maximum power reduced from 128 kW → 114 kW

Daily energy consumption reduced from:
2952 kWh → 2532 kWh

Energy saving rate: 14.2%

f8d6288b87d618839861f2e62dcf1dde

 

Annual Energy Savings

 

Annual saving: 147,000 kWh

Electricity cost saving: ≈ 13650$/year

Maintenance Savings

 

Gearbox lubrication & service: ≈ 457$/year