Motor Retrofit For Precursor Stirring Reactor Reduces Energy Consumption By 35%
Motor Retrofit for Precursor Stirring Reactor Reduces Energy Consumption by 35%
Motor Retrofit for Precursor Stirring Reactor Reduces Energy Consumption by 35%
Project Overview
In the tungsten precursor workshop, a high-power induction motor paired with a gear reducer was previously used in a stirred reactor. The system suffered from frequent maintenance, oil leakage, and high energy consumption. By retrofitting the system with a permanent magnet direct drive motor (PMSM), these issues were resolved, and energy consumption was reduced by 35%.
| Performance Comparison: | |||
| Parameter | Before (Induction Motor + Gear Reducer) | After (PMSM Direct Drive Motor) | |
| Rated Power |
|
45 kW | |
| Rated Voltage | 380 V | 380 V | |
| Frequency | 50 Hz | 50 Hz | |
| Rated Torque | 231 Nm | 2,626 Nm | |
| Rated Speed | 1,480 rpm | 200 rpm | |
| Gear Ratio | 7.59 | 1:1 | |
| Output Speed | 195 rpm | 195 rpm | |
| Energy Consumption | 17.13 kWh | 11.14 kWh | |

Key Benefits
- ✅ Eliminated gear reducer and oil leakage issues
- ✅ Reduced maintenance workload and downtime
- ✅ Greatly improved system torque and reliability