Permanent magnet synchronous motors are widely used in industrial and commercial applications due to their advantages such as energy efficiency and high power density. However, their stable operation relies on scientific maintenance. The following summarizes the key points of maintenance from four aspects: daily inspection, operation monitoring, environmental management, and regular maintenance:
1. Daily Inspection
Cleaning and tightening: Clean the dirt on the motor surface every day, check if the terminals and screws are loose or burned out, and ensure that the base is free of impurities, dust and sludge.
Bearing lubrication: Clean the bearings with kerosene every six months and replace it with fresh oil. After the first use of 10 to 15 days, the oil should be changed to avoid wear caused by insufficient lubrication.
Inspection of vulnerable parts: Regularly check the oxidation and contact conditions of contacts and terminals, and promptly repair damaged or poorly contacting parts.
2. Operation Monitoring
Insulation protection: Regularly measure the insulation resistance. If it is lower than 0.5 megohms, drying treatment should be carried out to prevent the winding from getting damp or corrosive gases from causing insulation failure.
Overload protection: Install overcurrent, overvoltage, short circuit and grounding protection devices to monitor current, voltage and temperature in real time. Automatically cut off the power supply when the limit is exceeded.
Temperature control: The motor temperature is monitored through a temperature sensor. When the temperature exceeds the limit, the machine will be shut down for maintenance to prevent demagnetization of the magnetic steel or aging of the windings due to high temperature.
3. Environmental Management
Ventilation and cooling: Ensure that the motor operates in a well-ventilated environment and that the air intake and exhaust paths remain unobstructed to prevent performance degradation or malfunction caused by overheating.
Moisture-proof and dust-proof: Keep the surface of the motor dry and avoid long-term exposure to damp or corrosive environments. Take sealing or protective measures when necessary.
4. Regular maintenance
Gear maintenance: Check the wear condition of the tooth surface every week. If the pitting or wear area exceeds 20%, the gear pair needs to be replaced.
Professional maintenance: Regularly replace the lubricant, conduct a comprehensive inspection of the motor, and replace missing or worn components to ensure long-term stable operation.